**奇美ABS PA-758英文物性表
Physical |
Nominal Value
|
Unit
|
Test Method
|
Specific Gravity
|
1.08
|
g/cm³
|
ASTM D792 |
Density
|
1.08
|
g/cm³
|
ISO 1183 |
Melt Mass-Flow Rate (MFR)
|
ASTM D1238 | ||
200°C/5.0 kg
|
3.0
|
g/10 min
|
|
220°C/10.0 kg
|
34
|
g/10 min
|
|
Melt Volume-Flow Rate (MVR) (220°C/10.0 kg)
|
34.0
|
cm³/10min
|
ISO 1133 |
Mechanical |
Nominal Value
|
Unit
|
Test Method
|
Tensile Strength 2 (3.18 mm)
|
39.6
|
MPa
|
ASTM D638 |
Tensile Stress (Yield)
|
42.0
|
MPa
|
ISO 527-2/50 |
Tensile Stress (Break)
|
33.0
|
MPa
|
ISO 527-2/50 |
Tensile Strain (Break)
|
50
|
%
|
ISO 527-2/50 |
Flexural Modulus 3 (6.35 mm)
|
1860
|
MPa
|
ASTM D790 |
Flexural Modulus 4
|
1500
|
MPa
|
ISO 178 |
Flexural Strength 3 (6.35 mm)
|
53.6
|
MPa
|
ASTM D790 |
Flexural Strength 4
|
56.0
|
MPa
|
ISO 178 |
Impact |
Nominal Value
|
Unit
|
Test Method
|
Charpy Notched Impact Strength
|
12
|
kJ/m²
|
ISO 179 |
Notched Izod Impact (23°C, 6.35 mm)
|
160
|
J/m
|
ASTM D256 |
Notched Izod Impact Strength
|
12
|
kJ/m²
|
ISO 180/1A |
Hardness |
Nominal Value
|
Unit
|
Test Method
|
Ball Indentation Hardness (H 358/30)
|
90.0
|
MPa
|
ISO 2039-1 |
Thermal |
Nominal Value
|
Unit
|
Test Method
|
Deflection Temperature Under Load (1.8 MPa, Unannealed, 6.35 mm)
|
87.8
|
°C
|
ASTM D648 |
Heat Deflection Temperature (1.8 MPa, Unannealed)
|
85.0
|
°C
|
ISO 75-2/A |
Heat Deflection Temperature (1.8 MPa, Annealed)
|
96.0
|
°C
|
ISO 75-2/A |
Vicat Softening Temperature 5
|
105
|
°C
|
ASTM D1525 6 |
Vicat Softening Temperature
|
|||
--
|
104
|
°C
|
ISO 306/A50 |
--
|
106
|
°C
|
ISO 306/A120 |
--
|
98.0
|
°C
|
ISO 306/B50 |
--
|
101
|
°C
|
ISO 306/B120 |
RTI Elec
|
UL 746 | ||
1.50 mm
|
60.0
|
°C
|
|
3.00 mm
|
60.0
|
°C
|
|
RTI Imp
|
UL 746 | ||
1.50 mm
|
60.0
|
°C
|
|
3.00 mm
|
60.0
|
°C
|
|
RTI Str
|
UL 746 | ||
1.50 mm
|
60.0
|
°C
|
|
3.00 mm
|
60.0
|
°C
|
|
Electrical |
Nominal Value
|
Unit
|
Test Method
|
Arc Resistance
|
6.00
|
sec
|
ASTM D495 |
Comparative Tracking Index (CTI)
|
PLC 0
|
UL 746 | |
High Amp Arc Ignition (HAI)
|
UL 746 | ||
1.50 mm
|
PLC 3
|
||
3.00 mm
|
PLC 3
|
||
High Voltage Arc Tracking Rate (HVTR)
|
PLC 0
|
UL 746 | |
Hot-wire Ignition (HWI)
|
UL 746 | ||
1.50 mm
|
PLC 4
|
||
3.00 mm
|
PLC 3
|
||
Flammability |
Nominal Value
|
Unit
|
Test Method
|
Flame Rating
|
UL 94 | ||
1.50 mm, ALL
|
HB
|
||
1.59 mm
|
HB
|
||
3.00 mm, ALL
|
HB
|
||
Optical |
Nominal Value
|
Unit
|
Test Method
|
Transmittance (3180 µm)
|
90.0
|
%
|
ASTM D1003 |
Haze (3180 µm)
|
4.0
|
%
|
ASTM D1003 |